We just got our second BSOD on a failovercluster box in 2 weeks. The setup is 3 server 2012 boxes (dell r610) with a 10 gig nic for san and the onboard for the public.
the minidump shows netft.sys as the culprit
ADDITIONAL_DEBUG_TEXT: You can run '.symfix; .reload' to try to fix the symbol path and load symbols. MODULE_NAME: netft FAULTING_MODULE: fffff802f5683000 nt DEBUG_FLR_IMAGE_TIMESTAMP: 5010aa07 PROCESS_OBJECT: fffffa80ac6e46c0 CUSTOMER_CRASH_COUNT: 1 DEFAULT_BUCKET_ID: WIN8_DRIVER_FAULT_SERVER BUGCHECK_STR: 0x9E CURRENT_IRQL: 0 LAST_CONTROL_TRANSFER: from fffff8800660d845 to fffff802f56dd440 STACK_TEXT: fffff880`0316a938 fffff880`0660d845 : 00000000`0000009e fffffa80`ac6e46c0 00000000`0000003c 00000000`00000000 : nt+0x5a440 fffff880`0316a940 00000000`0000009e : fffffa80`ac6e46c0 00000000`0000003c 00000000`00000000 00000000`00000000 : netft+0x2845 fffff880`0316a948 fffffa80`ac6e46c0 : 00000000`0000003c 00000000`00000000 00000000`00000000 fffff802`f5636dd4 : 0x9e fffff880`0316a950 00000000`0000003c : 00000000`00000000 00000000`00000000 fffff802`f5636dd4 fffffa80`4cdecc30 : 0xfffffa80`ac6e46c0 fffff880`0316a958 00000000`00000000 : 00000000`00000000 fffff802`f5636dd4 fffffa80`4cdecc30 fffff880`0660d516 : 0x3c STACK_COMMAND: kb FOLLOWUP_IP: netft+2845 fffff880`0660d845 ?? ??? SYMBOL_STACK_INDEX: 1 SYMBOL_NAME: netft+2845 FOLLOWUP_NAME: MachineOwner IMAGE_NAME: netft.sys
Any thoughts on what i should do?